| Designed in
an innovative modular fashion, Falco controller allows you
to upgrade your system anytime from 1 to 10,000 doors by connecting
to server via TCP/IP Local Area Network configuration and manage by Falco
Premium System software. This modular, cost-efficient
upgrade strategy ensures that you can always keep pace with
your emerging security requirements while meeting your ongoing
budgetary objectives. Its wide capabilities make it suitable
for even the largest, most complex building architectures
and the most demanding security requirements.
The FALCO IP door controller has 2 wiegand
reader ports with one in and one out, and has a space for either the entry or exit
reader to be mounted. The controller can be configured to
work with almost all reader technologies without hardware
change - including with Wiegand, ABA track 2 and contact-less
Read/ Write smart card.
This IP controller provides direct
communication through TCP/IP network. Each controller will
consist of it's own IP address. Communication speed as compare
to RS-485 is faster (100 Mbit/s).
Advanced Design
The Falco door controller uses the latest state-of-the-art
flash memory technology which allows firmware upgrade. Essential
equipment settings, card database and transaction database
are stored in EEPROM, so that there is no loss of data during
power outage.
Multiple Entry Access Mode
There are 3 different entry access modes that you can set
to adjust to your security requirements: Card only, PIN only
and Card & PIN only. This means a door can be programmed
to operate on different entry access mode at either same or
different time for each day of the week, including weekends
and holidays. For example, a door can be programmed to operate
on 'Card only' entry mode during office hours but automatically
switch to 'Card & PIN only' entry mode after office hours.
Use of Single Card to Perform Multiple
Functions
The prowess of the Falco door controller is its ability to
allow a single card to perform multiple functions through
software control. The types of functions consist of normal
access control, programming, Arm/Disarm, guard tour, etc.
Schedules Settings
Up to 50 sets of weekly timers, where each daily timer consists
of 3 sets of start and stop time interval settings can be
used for system behavior control. These timers are also tagged
to a day-of-week selection, which are used for all timers'
related operations, such as locking and unlocking of doors,
activating of User PIN function, etc.
Quite often you may want to unlock the office
main entrance door during office hours, but the door shall
be locked during lunch break and after office hours. This
requirement can be achieved through timer(s) controls.
Alarm Monitoring Function
Alarm monitoring functions become available when Falco controller
is operated from Falco PC software. Each Falco controller
is equipped with 8 supervised inputs and 4 relay output. Since
the maximum system size for Falco controller is 100 doors,
such a system will have 800 input points and 400 output points
for alarm monitoring usage. Users can set complex combination
from Falco PC software. Thereafter, arming or disarming of
alarm zones, and switching on or off output groups can be
performed from any reader PIN keypad connected to the Falco
controller.
Power Supply
Falco Controller comes with battery charging and a power regulation
circuit. The input power requirement is 14VAC, and a lead-acid
battery can be connected to the charger output. In addition,
AC power failure, low battery cut off and battery low status
sensing are built-in.
10-Digit MIFARE
Falco Controller now able to reads 10-digit card number
instead of 6-digit. The more digit it can read, lower the
possibility of reading duplicate card number.
This will reduce the chances of
number repeats or duplicates in large card volume. Identities
mismatch might happen when there are duplicates card number
and this will cause error to attendance report.
- MCU :
Motorola/
Freescale 16-bit CPU Running at 25Mhz
-
Memory : 64KB FlashROM, 8KB RAM, 32KB EEPROM
- Watchdog : 1 Internal
-
Operating
Temperature: 0?/span>C
to 60?/span>C
-
Humidity
Range: 0-95% non-condensing
-
Protocol
Support: TCP, IP, UDP, DHCP, ICMP, and ARP
- Network Interface : TCP/IP, LAN, WAN
-
Communication Interface : Onboard Ethernet Port
(TCP/IP)10/100BaseT
- Relay Output :
10A (1
Form C- can configured to NC or NO)
- Power Supply : 14VAC input, 13.8V output, 1.5 ~ 3.0A
output
- Current Consumption :
200-300mA
(without the EM Lock)/1.5A max
- Dimensions : 50mm(H) x 152mm(W) x 127mm(D)
-
Configurable : 1-door or 2-door (with expansion board) and
alarm monitoring
-
Supervised Input :2 Supervised input (Onboard)
-
Digital
Input : 3 Input
-
Output :
2 Relay Output (Onboard), 3 Open-Collector Power Output
(100mA-Onboard)
- Large Memory : Stores up to 150,000 user cards and 80,000
transactions
- Power
Fault Detection: Loss of AC Power and battery voltage low
- PIN only, Card only, and Card Plus PIN Operation Modes
- Lock-out of a card when its PIN is wrongly entered
repeatedly
|
Features |
Benefits |
|
Going
Digital |
Evolution from conventional or obsolete RS-485 or RS-232
based technology to future proof Falco IP system. |
|
Cost-Efficient Infrastructure |
Most
facilities are already wired with twisted-pair
infrastructures, so with IP access control no additional
wiring is required. |
|
Scalability LAN / WAN architecture |
IP
access control scales from one to hundreds of IP door
access control in the increments of single controller.
|
|
Global
Antipassback |
Global
Antipassback without the need of PC online 24 hours.
Eliminates chances of failure when PC down. |
|
Reduces
Bandwidth |
High
speed communication up to 100MB/s will reduce the Network
Bandwidth usage. |
|
High
Speed Polling |
Data
are transmitted in bulk therefore increase the speed of
data transmission from controller to PC. This provides a
real-time transactions event to the user. |
|
Peer to
Peer Controller Communication |
Between
controllers, they can communicate with each other.
Therefore alarm signals can be sent in betweens controller
without PC to be online. |
|
Wireless Networking |
Wireless can be use to save cable cost and also enable IP
controller to be connected to those area where hardwire
wiring is not permissible such as museum. |
|
Pattern
Card Searching Algorithm |
For
100k user system with our patterned card searching
algorithm, user can open the door in less than a second
upon proxing on the card reader |
|
Integrated Power Supply Module |
Monitor
AC failure and low battery. Battery cut-off feature. 3A
supply and able to drive 2 electromagnetic-lock. |
|
Star
Topology |
A
controller will not affect the other controller
communication as compare with Daisy Chain or looping
between the controllers. Therefore it is easy to service
and troubleshoot. |
|
Remote
Site Access |
With
the available network infrastructure, we can remote access
and monitor branches from HQ via the internet/broadband.
Also process data in HQ. By concentrating the monitoring
of a number of buildings into a single location, client
costs are reduced. |
|
3rd
Parties Software |
Information or data collected in the server can be export
to 3rd party’s software such as HR and payroll. |
|
Graphic
User Interface |
Powerful yet Easy-To-Use GUI. Uses windows based GUI which
is just point and click. |
|
Auto
Detects |
No need
to set the jumper on controller to address it. It will
auto detect the respective IP on the board. Which means
you do not have to set the IP number, if use our default
IP and it will automatically save this in the database.
The conventional 485 way you have to set the jumper and
also remember the jumper address before you can install
it. |
|
More
Secure |
Our
relay or door controller is inside the premises. Some low
end product, the controller and relay are together. If you
tamper with the relay using the magnet, you can easily
open the door or damage the system. |
|
Ethernet Physical Transceiver (EPHY) |
Integrated
10/100 Mbps Ethernet physical transceiver (EPHY) to our
processor. If a signal converter is use to convert theRS/232
or 485 signal to TCP/IP the maximum speed is 115 K/B
compare with 100 M/B for the integrated EPHY. Software
driver will be required to intercept theRS/232 or 485
protocols to be converted to IP protocol. This not only
slows down the system but reduce the reliability of the
system.
|
|
Auto Setup
|
Our
Falco IP software is intelligent enough to set the PC IP
to our default IP address system. No network IT specialist
is required. |
|
10 Digit Card
|
10-digit card number where this will reduce the chances of
number repeats or duplicates in large card volume.
Identities mismatch might happen when there are duplicates
card number and this will cause error to attendance
report. It's all-in-one-card 13.56MHz contact-less smart
card technology provides highly secure encryption options,
scalability, multi-application support and unrivaled
application flexibility. |
FALCO-CTRL-1DRSMT-TCP/IP(3.0A)
: Normal Access Controller uses TCP/IP
 |